Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
post

VRC-Mix LP

Advanced Variable Ratio Electronic Two Component Equipment

  • Accurate component metering by precision geared flow meters
  • Reliable online mixing ratio assurance
  • Easy to use user friendly touch screen operator interface.
  • Material usage reporting
  • Multi colour operation quick colour change, with preset recipe.
COMPARISONMANUAL MIXINGVRC-MIX
Online Ratio assuranceNoYes
Fresh material mixing on demandNoYes
Pot life monitorNoYes
Material usage reportNoYes
Paint/ solvent wastageHighNo
Colour change, configuration & setup time.HighVery low
Labour costHighLow
FEATURESSTANDARDOPTIONAL (ON REQUEST)
Mixing Ratio RangeUP to 30.0( in 0.1 increments) 
Accuracy toleranceDown to 1 % * User settable 
Flow rate0.1 to 4 liters per minuteHigher flow rates
Maximum Fluid pressureAir spray system – 30 bar Air assisted airless – 200 bar 
Air pressure requirement4-7 bar 
Electrical power requirement230 V AC 50 Hz Single PhaseAs per available power source
Multi-colour application (colour change facility)4 colours,4 hardeners &2 solvents,4 different recipes can be storedModular system. Extra colour and recipe addition
flushingManual as well as inbuilt auto flushing cycle programmable sequential air-solvent purge 
Material usage reporting.Reporting of component consumption accumulative.+ daily consumption 
Pot life monitoringPot life monitoring of mixed material 
Pressure monitoringOnline system health checking by pressure monitoring. 
Level monitoringOnline container level monitoring based on material consumption. 
Remote operator panelEx-proof remote operator panel
communicationRS 232 communication port for printer/network/PC. Protocol ModbusSCADA
Operator InterfaceTouch screen graphical display with audio visual alarm svstem
FaultsAlarmSystem Response
Off-mixing ratioAudio + Visual alarm with text messageAuto shut off
Pot life nearing to endAudio + Visual alarm with text message
Pot life endAudio+ Visual alarm with text messageAuto shut off
Container nearing to emptyAudio+ Visual alarm with text message
Container emptyAudio+ Visual alarm with text messageAuto shut off
Surpass of set pressure limitsAudio + Visual alarm with text messageAuto shut off
Other system faults &InterlocksAudio+ Visual alarm with text messageAuto shut off

Feel Free to contact us

Have questions about our services or a project that needs quoting? Answers are always just an email or phone call away